An electrical layout plan marks every switch board, light, fan, socket, AC, geyser and TV point on the floor plan, with its height from the floor. In Indian homes the switch board is usually about 4 ft (1.2 m) up, sockets about 1 ft, the AC point about 7 ft and the geyser point about 6 ft. A licensed electrician confirms the final wiring.
The studio below opens on a 2BHK with the usual points already placed in every room. Open a room to move, add or remove points, add wire joints, and see the schedule of points, the wire runs and an indicative load.
| Point | Usual height from floor | Note |
|---|---|---|
| Switch board for lights and fans | 4 to 4.5 ft (1.2 to 1.35 m) | Beside the door, on the side it opens from |
| Bedside switches | 2.5 to 3 ft | For a reading light and a charger |
| 6A sockets | 1 to 1.5 ft (300 to 450 mm) | Lamps, chargers, small appliances |
| 16A power sockets | 1 to 1.5 ft; in the kitchen above the counter | Fridge, washing machine, microwave, iron |
| Kitchen counter sockets | About 1 ft above the counter, about 4 ft from the floor | Clear of the sink and hob |
| TV point | 3.5 to 4 ft, behind the TV | With a data or cable point beside it |
| AC point | About 7 ft | Near one end of the indoor unit |
| Geyser point | About 6 ft | Out of reach of splashing water |
| Exhaust fan | About 7 ft | High on an outside wall |
| Wall light | 6 to 6.5 ft | |
| Bell point | About 5 ft | By the main door |
These are usual heights, not rules. Rules for safety, such as how low a board may sit in a bathroom, come from IS 732 and your state's electrical rules, which your electrician follows.
| Room | Usual points | What they cover |
|---|---|---|
| Master bedroom | 10 to 16 | 2 to 3 lights, fan, AC, bedside switches and sockets on both sides, 2 to 3 sockets, TV |
| Other bedroom | 8 to 12 | Lights, fan, AC, bedside socket, study table socket |
| Living room | 10 to 15 | Lights, 1 or 2 fans, AC, TV and data, sockets, wall lights |
| Kitchen | 10 to 14 | Light, chimney or exhaust, fridge, microwave, mixer, water purifier, induction |
| Dining | 4 to 6 | Pendant light, fan, a socket |
| Bathroom | 4 to 6 | Light, mirror light, exhaust fan, geyser, a socket away from water |
| Balcony or utility | 3 to 5 | Light, washing machine socket, a socket |
| Whole 2BHK | About 38 to 50 | Counting every switch, socket and point |
Ranges from builders' and electricians' planning guides in India. What you will plug in decides the count: list the appliances in each room first, then add one or two spare sockets.
Usually 4 to 4.5 ft (1.2 to 1.35 m) from the finished floor for light and fan switches. Some state rules ask that an open board's bottom be at least 1.25 m up; your electrician will know your state's rule.
Interior and turnkey businesses on Inbecto download designs free, price them from their own rates and send them to clients to approve. See Inbecto for businesses
Typical room sizes in Indian flats.
What a bill of quantities (BOQ) is, the columns it has, the units used for each trade in India, a sample BOQ, and how a BOQ differs from an estimate and a quotation..
How interior work is measured and priced in India.
House front elevation design online.
Electrical, interior and turnkey contractors on Inbecto turn this layout into a quotation with every point and wire run priced. Book a short demo to see it on your own project.
Inbecto turns a design into a priced quotation, sends it to the client to approve, and carries it through the project to the GST invoice and payment.